++APAR(ASZ3051). /*--------------------------------------------------- COPYRIGHT AUSTRALIAN SYSTEMS ENGINEERING PTY. LTD. 1998. ASZ3051 981110 61VTEL BN OMCSV2 P613 INCORROUT OMCSDBIM 981218 A__-PMD After OMCSDBIM restore, OMCSDBVR may report directry sequence error and duplicate directry entry errors. _PROBLEM DESCRIPTION: OMCSDBVR reports directry sequence errors and duplicate directry entries. OMCSDBIM is inserting directry entries for restored files in the wrong position. _PROBLEM SUMMARY: USERS AFFECTED: ALL During a restore operation, OMCSDBIM inserts a directry entry in the wrong position if the file already exists in the database and is being replaced. This only occurs if the database has a large number of directry entries. During the replacement, a buffer containing the current file name is flushed causing the program to position to the wrong place to insert the directry entry. _PROBLEM CONCLUSION RECOMMENDATION: Apply apar ASZ3051. OMCSDBIM will be changed to copy the current filename to a workarea during the replace operation. NEED FURTHER HELP? CALL ASE FOR ASSISTANCE or email help@ase.com.au */ ++VER(Z038) FMID(ASEB200) PRE(ASP0757). ++ZAP(OMCSDBIM). NAME OMCSDBIM IDRDATA ASZ3051 VER 4352 D50F8000 VER 447E D50F8000 REP 4352 D50FA100 REP 447E D50FA100 *LMOD OMCSDBIM