++APAR(ASZ3377). /* ---------------------------------------------------- COPYRIGHT AUSTRALIAN SYSTEMS ENGINEERING PTY. LTD. 2005. ASZ3377 050228 61VTEL MC ASEB200 V210 ABS906 ASEDAMGR 050228 s__-PMD Msg CSV002I REQUESTS FOR MODULE OMCSARC EXCEED MAXIMUM USE COUNT _PROBLEM DESCRIPTION: OMCS writer abends with abend code s906 and msg CSV002I is issued for module OMCSARC after 5 days of processing. _PROBLEM SUMMARY: USERS AFFECTED: All users with writers processing multiple databases Each time the writer switches databases it shuts down the current database session and starts a new session with the new database. Session initialization loads a number of modules including OMCSARC. Session shutdown should delete these modules. Due to an incompatability in macros used to load and delete these modules, the modules were not deleted and their use counts exceeded the maximum value causing the message and abend. _PROBLEM CONCLUSION RECOMMENDATION: Apply APAR fix ASZ3377. ASEDAMDM will be changed to use the correct macro to delete the modules at shutdown. NEED FURTHER HELP? CALL ASE FOR ASSISTANCE. */ ++VER(Z038) FMID(ASEB200) PRE(ASP0998). ++ZAP(ASEDAMDM). NAME ASEDAMDM IDRDATA ASZ3377 VER 2196 9180A570 VER 21B2 9180A578 VER 21CE 9180A580 VER 21EA 9180AF40 REP 2196 9180A574 REP 21B2 9180A57C REP 21CE 9180A584 REP 21EA 9180AF44 *LMOD ASEDAMGR